Anodically Protected Acid Cooler with Corrosion Prevention, Extended Equipment Life, and Efficient Thermal Transmission for Sulfuric Acid Plants First Absorption Acid Cooler
|
Process parameters |
||||||||
|
Project |
Design parameters |
Performance parameters |
||||||
|
|
Shell Side
|
Tube Side
|
Shell Side
|
Tube Side
|
||||
|
MEDIUM |
Fluid name |
Sulfuric Acid
98.5%
|
Demineralized Water
|
Sulfuric Acid
98.5%
|
Cooling Water
|
|||
|
|
Temperature (Inlet) ℃ |
80
|
45
|
80
|
45
|
|||
|
|
Temperature (Outlet)℃ |
72
|
|
72
|
68.522
|
|||
|
|
Liquid Kg/h |
1791000
|
220000
|
1791000
|
220000
|
|||
|
|
Density(inlet/outlet) Kg/m3 |
1791
|
1000
|
1791
|
1000
|
|||
|
|
Viscosity(inlet/outlet)(cp) |
7.45/10.82
|
0.76
|
7.45/10.82
|
0.76
|
|||
|
|
Inlet pressure Mpa |
0.4
|
0.3
|
0.4
|
0.3
|
|||
|
|
Pressure drop, Mpa |
≤0.1
|
≤0.1
|
0.072
|
0.002
|
|||
|
PERFORMANCE |
Heat exchanged quantity W |
|
~5989900.0
|
|||||
|
|
Flow rate m/s |
|
0.590
|
0.411
|
||||
|
|
Heat transfer area affluent coefficient |
|
1.1
|
|||||
|
|
Heat transfer coefficient W/m2 ℃ |
|
959.367
|
|||||
|
|
Heat transfer area m2 |
|
410
|
|||||
|
MATERIAL |
Type |
shell and tube
|
The flow form
|
Counter-current flow
|
||||
|
|
Sealing form |
welding connection in acid side, flange connection in water side
|
||||||
|
|
|
shell
|
304L δ= 10
|
|||||
|
|
|
Heat transfer tube
|
316L Φ19×2.0×6000
|
|||||
|
|
|
Tubesheet
|
304L δ= 55
|
|||||
|
|
|
Baffle-crossing
|
304L δ= 10
|
|||||
|
|
|
head
|
Q235-B δ= 12
|
|||||
|
|
|
Shell Side
|
Tube Side
|
|||||
|
|
|
HG/T20592-2009(B) PN16 DN 600
|
HG/T20592-2009(B) PN10 DN 200
|
|||||
|
Size |
Φ1400×5794×1878
|
|||||||
|
Operating weight |
17761 Kg
|
|||||||
|
The scope of supply |
●Complete set ●Control system
●Special cable ●Random accessories
|
|||||||
Anodically Protected Acid Cooler